Skip to content

The Neural Correlates of Consciousness: A Spectral Exponent Approach to Diagnosing Disorders of Consciousness.

Ying Zhao, Anqi Wang, Weiqiao Zhao, Nantu Hu, Steven Laureys, Haibo Di

Brain Sciences April 4, 2025 DOI: 10.3390/brainsci15040377 (opens in new tab)

Study at a glance

AI-extracted from the abstract
Characteristics Observational cohort Longitudinal Peer reviewed
Sample size 47
Population Patients with disorder of consciousness, conscious brain-injured controls, and healthy controls
Keywords EEG Biomarker Disorder of consciousness Spectral exponent Brain monitoring Consciousness research Medical diagnostics EEG Analysis
Citations 5
Key findings Narrowband spectral exponent (1-20 Hz) differentiates disorder of consciousness patients from controls and minimally conscious from vegetative/unresponsive states, and correlates with behavioral consciousness scores.

Abstract

Disorder of consciousness (DoC) poses diagnostic challenges due to behavioral assessment limitations. This study evaluates the spectral exponent (SE)-a neurophysiological biomarker quantifying the decay slope of electroencephalography (EEG) aperiodic activity-as an objective tool for consciousness stratification and clinical behavior scores correlation. The study involved 15 DoC patients, nine conscious brain-injured controls (BI), and 23 healthy controls (HC). Resting-state 32-channel EEG data were analyzed to compute SE across broadband (1-40 Hz) and narrowband (1-20 Hz, 20-40 Hz). Statistical frameworks included Bonferroni-corrected Kruskal-Wallis H tests, Bayesian ANOVA, and correlation analyses with CRS-R behavioral scores. Narrowband SE (1-20 Hz) showed superior diagnostic sensitivity, differentiating DoC from controls (HC vs. DoC: p < 0.0001; BI vs. DoC: p = 0.0006) and MCS from VS/UWS (p = 0.0014). SE correlated positively with CRS-R index (1-20 Hz: r = 0.590, p = 0.021) and visual subscale (1-20 Hz: r = 0.684, p = 0.005). High-frequency (20-40 Hz) SE exhibited inconsistent results. Longitudinal tracking in an individual revealed a reduction in SE negativity, a flattening of the 1/f slope, and behavioral recovery occurring in parallel. Narrowband SE (1-20 Hz) is a robust biomarker for consciousness quantification, overcoming behavioral assessment subjectivity. Its correlation with visual function highlights potential clinical utility. Future studies should validate SE in larger cohorts and integrate multimodal neuroimaging.

Citations in the library