Awareness during general anesthesia despite simultaneous bispectral index and end-tidal anesthetic gas concentration monitoring.

Jungwon Lee, Chorong Park, Saeyoung Kim

Yeungnam University journal of medicine 2019 DOI: 10.12701/yujm.2019.00010 (opens in new tab)

Study at a glance

AI-extracted from the abstract
Characteristics Case study Case report Peer reviewed
Sample size 1
Population 80-year-old man undergoing total gastrectomy
Interventions desflurane nitrous oxide
Dose desflurane 4.0-5.0% vol, ETAG 0.9-1.2 MAC
Measures BIS, ETAG
Keywords Anesthesia Awareness Consciousness monitors
Key findings Awareness during anesthesia occurred despite BIS maintained at approximately 40 and ETAG at 0.7-1.3 MAC.

Abstract

Awareness during general anesthesia occurs in approximately 0.1-0.2% of cases; nevertheless, particular attention is required because it can lead to critical complications including insomnia, depression, anxiety, and post-traumatic stress disorder. To prevent these complications, bispectral index (BIS) and end-tidal anesthetic gas (ETAG) concentration monitoring are commonly used to examine patient consciousness during surgery. In the present case, an 80-year-old man was scheduled for total gastrectomy. Anesthesia was maintained using desflurane 4.0-5.0% vol, oxygen, and nitrous oxide. The authors simultaneously monitored BIS, which was maintained between 37 and 43, and ETAG, which was maintained between 0.9 and 1.2 minimum alveolar concentration (MAC). After the operation, however, the authors were surprised to learn that the patient complained of awareness during anesthesia. Although BIS and ETAG concentration monitoring are useful in preventing awareness during anesthesia, they cannot be completely trusted. Even though BIS was maintained at approximately 40 and ETAG at 0.7-1.3 MAC, awareness during anesthesia occurred.

Explore topics