Mindscape Collective is now The Consciousness Library. Same library, new name. You may need to sign in again. About the change
Skip to content

Comparison of the Characteristic Mass Fragmentations of Phenethylamines and Tryptamines by Electron Ionization Gas Chromatography Mass Spectrometry, Electrospray and Matrix-Assisted Laser Desorption Ionization Mass Spectrometry

Bo-Hong Chen, Ju-Tsung Liu, Hung-Ming Chen, Wen-Xiong Chen, Cheng-Huang Lin

Applied Sciences June 22, 2018 DOI: 10.3390/app8071022 (opens in new tab) via OpenAlex

Summary

AI-generated from the abstract

Three analytical methods—matrix-assisted laser desorption/time-of-flight mass spectrometry, gas chromatography–electron ionization–mass spectrometry, and liquid chromatography–electrospray ionization/mass spectrometry—were compared for characterizing 20 phenethylamine and tryptamine standards. For GC-EI/MS, three characteristic peaks (the molecular ion and fragments from Cβ-Cα bond breakage) uniquely identified 2C series compounds. For ESI/MS and MALDI/TOFMS, the protonated molecular ion and fragments from α-cleavage and β-cleavage provided useful information for rapid screening and confirmation of phenethylamine and tryptamine derivatives. The assay successfully determined samples containing illicit drugs.

Study at a glance

Characteristics Method comparison study Peer reviewed
Population 20 phenethylamine and tryptamine standards
Citations 10
Key finding Characteristic mass fragments from Cβ-Cα bond breakage uniquely identify 2C series compounds by GC-EI/MS, while α-cleavage and β-cleavage fragments aid screening by ESI/MS and MALDI/TOFMS.

Abstract

Characteristic mass fragmentation of 20 phenethylamine/tryptamine standards were investigated and compared by means of matrix assisted laser desorption/time-of-flight mass spectrometry (MALDI/TOFM), gas chromatography–electron ionization–mass spectrometry (GC-EI/MS) and liquid chromatography–electrospray ionization/mass spectrometry (LC-ESI/MS) methods. As a result, three characteristic peaks ([M]+ and fragments from the Cβ-Cα bond breakage) were found to be unique and contained information useful in identifying 2C series compounds based on the GC-EI/MS method. We found that the protonated molecular ion ([M+H]+) and two types of fragments produced from the α-cleavage and β-cleavage processes were useful mass spectral information in the rapid screening and confirmation of phenethylamine and tryptamine derivatives when ESI/MS and MALDI/TOFMS methods were applied. This assay was successfully used to determine samples that contain illicit drugs.

Comments

No comments yet.

Log in to comment